How much a wind or solar farm will produce, and how sure that figure is.

Skerrow is an independent technical adviser for wind and solar projects. Our energy yield assessments let a developer decide whether to build, and a bank decide how much to lend.

Carrick Law Wind Farm

Energy Yield Assessment. Scottish Borders, 58.8 MW

Gross yield

236.4

GWh a year

Losses

15.4%

Net yield, P50

200.0

GWh a year

Capacity factor

38.8%

Share of the year’s production by month

Net yield over ten years

GWh a year

P50
200.0
P75
187.6
P90
176.4
P99
157.2

Ten-year uncertainty 9.2%

Developers, lenders, infrastructure funds, utilities and community energy groups rely on our reports.

What clients say
  • Northmoor Renewables
  • Halewind
  • Verrano Solar
  • Brightmere Infrastructure
  • Castellan Project Finance
  • Tidewell Energy
  • Solveig Kraft
  • Meridiem Power
  • Lowther Community Energy
  • Orrin Offshore

Six services, from a first estimate to a farm that is already running

Most of our projects are in the United Kingdom, Ireland, Germany, the Nordic countries, Spain and Poland.

  • Net yield

    Hollin Bank Solar Farm

    P50
    63.1 GWh a year
    Ten-year P90
    58.6 GWh

    For projects with or without storage

    Energy Yield Assessment

    The long-term net production of a wind or solar project before it is built.

  • In the field

    41 masts and 23 lidar units, November 2026

    Solar measurement stations

    Data checked every working day

    A fault reported within 24 hours

    Measurement Campaigns

    Design, installation and daily monitoring of the instruments on a site.

  • Review

    Re-run from the raw data

    Where we agree
    Where we do not
    Call with the credit committee

    Lender’s Technical Review

    An independent review of an assessment somebody else wrote.

  • Production data

    At least 12 months of the farm’s own data

    Used for refinancing, for a sale, and to find production that is being lost.

    Operational Reassessment

    A new estimate for a farm that is already running.

  • First P50, with its range

    Delivered in 5 working days

    A note on what to measure

    Site Screening

    A first estimate for a site with no measurements yet.

  • One grid connection

    What the site would produce

    New turbinesSolar addedStorage added

    Repowering and Hybrid Studies

    What a site would produce with new turbines, or with solar or storage added.

Who we work for

Five kinds of client, and what each asks us for.

A developer reading a map on a gate at the edge of an upland field

Developers

Which sites to measure, and a report a lender will accept.

A lender reading a bound report at a desk by a window

Lenders

An independent check before financial close, and answers for the credit committee.

Two colleagues at a fund looking over printed charts on a table

Infrastructure funds

What a portfolio is really worth before a purchase.

An engineer in a high-visibility jacket on a hillside, with older wind turbines far behind her

Utilities

Repowering old farms, and adding solar or storage to a grid connection.

Three neighbours talking round a table of papers in a village hall

Community energy groups

A bankable report at a fee a small project can carry.

No projects of our own, no equipment to sell, and no fee that depends on the answer.

Projects owned
None
Equipment sold
None
Fee that depends on the answer
None

Adviser for wind and solar projects

Independent

We own no projects, sell no equipment and take no fee that depends on the answer.

Final report

With a reliance letter for the lender

Author

Checker

Signed by two engineers

Every report is signed by the two engineers who wrote and checked it.

Produced, on average, across 212 operating farms

99.6%

of our P50 estimate

Within 6% of their estimate88%

Checked against production

Every year we publish how our past estimates compared with what the farms actually produced.

The 2026 validation study

What a report holds

Our main product is a report, the energy yield assessment: how much electricity a wind farm or a solar farm will produce over its life, and how sure that figure is.

  • The measurements used, and how each instrument’s data was checked and cleaned.
  • The long-term correction: how the measured period compares with the last 20 years or more.
  • The gross yield, then each loss by name: wakes, availability, electrical, turbine or panel performance, environmental, and curtailment.
  • The net yield as P50, P75, P90 and P99, for one year and for ten.
  • The uncertainty, itemised, with the sources that contribute most.
  • A monthly and hourly production profile.
  • Signatures of the author and the checker, and a reliance letter for the lender where one is needed.

A worked example: Carrick Law Wind Farm

Scottish Borders. 14 turbines of 4.2 MW, 58.8 MW in all, at a hub height of 105 m. Measured for 24 months with an 80 m mast and a lidar unit. The six losses, taken together, remove 15.4% of the gross yield.

See what an assessment costs

From gross yield to net

Carrick Law Wind Farm, GWh a year

Gross yield
236.4 GWh
Wakes
−7.9%
Availability
−3.0%
Electrical
−2.1%
Turbine performance
−1.4%
Environmental
−1.1%
Curtailment
−0.8%
Six losses, taken together
−15.4%
Net yield, P50
200.0 GWh

Long-term mean wind speed at hub height

8.1 m/s

A worked example: Hollin Bank Solar Farm

Lincolnshire. 62.4 MWp of panels on single-axis trackers, 49.9 MW at the grid connection. Sunshine on a flat surface: 1,084 kWh for each square metre a year.

Request an assessment

Hollin Bank Solar Farm

Energy Yield Assessment. Lincolnshire, 62.4 MWp

Specific yield

1,012

kWh for each kWp a year

Net yield, P50

63.1

GWh a year

Ten-year P90

58.6

GWh

Ten-year uncertainty

5.6%

Performance ratio83.4%

What an assessment looks at differs with the technology

Onshore wind

Measurements from masts and lidar units on the site. The model covers:

  • The terrain
  • The wakes between turbines
  • The hours a farm must slow down or stop for noise or shadow
Request an assessment

Offshore wind

Measurements from floating lidar and from satellites. The model covers:

  • Wakes from neighbouring farms as well as within the farm
  • The days a crew cannot reach a turbine by sea
Request an assessment

Solar

Sunshine measured from satellites and on the ground. The model covers:

  • Shading
  • Dirt on the panels
  • Losses in trackers and inverters
  • The panels’ loss of output over the years
Request an assessment

How an assessment goes

Six steps, from a free scoping call to a report signed by both engineers. The draft comes four weeks after the data is complete.

Data request
scoping call
30 minutes, free
list of data
one working day
data room
secure

Site visit

Every instrument

Cleaned and corrected

To the long term

Modelled across the site

One writesOne checks
Draft reportFinal reportReliance letter

1. Scoping call

Thirty minutes with an engineer, free, to agree what the report is for and who will rely on it.

2. Data request

Within one working day you get a short list of the data needed and a secure data room to put it in.

3. Site visit

An engineer visits the site and every instrument on it. For a solar farm of 50 MW or less the visit may be replaced by the installer’s photographs.

4. Analysis

The measurements are cleaned, corrected to the long term and modelled across the site. Two engineers work on every report: one writes, one checks.

5. Draft report

Four weeks after the data is complete, with a call to go through it.

6. Final report

Signed by both engineers, with a reliance letter for the lender. Questions from the lender’s own adviser are answered for 12 months at no charge.

Data request
scoping call
30 minutes, free
list of data
one working day
data room
secure

1. Scoping call

Thirty minutes with an engineer, free, to agree what the report is for and who will rely on it.

2. Data request

Within one working day you get a short list of the data needed and a secure data room to put it in.

Site visit

Every instrument

Cleaned and corrected

To the long term

Modelled across the site

One writesOne checks

3. Site visit

An engineer visits the site and every instrument on it. For a solar farm of 50 MW or less the visit may be replaced by the installer’s photographs.

4. Analysis

The measurements are cleaned, corrected to the long term and modelled across the site. Two engineers work on every report: one writes, one checks.

Draft reportFinal reportReliance letter

5. Draft report

Four weeks after the data is complete, with a call to go through it.

6. Final report

Signed by both engineers, with a reliance letter for the lender. Questions from the lender’s own adviser are answered for 12 months at no charge.

Stage 1 of 3: 1. Scoping call, 2. Data request

Our fees, and what each one covers.

All fees are in pounds sterling and exclude VAT.

  • Site Screening

    A first estimate for a site with no measurements yet.

    £3,900a site

    Fixed. Delivered in five working days.

    • Modelled wind or sunshine data for the site
    • A first P50 with its range
    • A note on what to measure and for how long
    Request a screening
  • Energy Yield Assessment

    One fixed fee, agreed before work starts.

    From£14,500

    For a solar farm of up to 50 MW. From £24,000 for an onshore wind farm of up to 100 MW.

    • A site visit
    • Cleaning and long-term correction of the measurements
    • Every loss and the uncertainty
    • P50 to P99
    • A reliance letter for one lender
    • Answers to the lender’s adviser for 12 months
    Request an assessment
  • Lender’s Technical Review

    For a bank or a fund ahead of financial close.

    From£9,800

    An independent review of an assessment somebody else wrote.

    • The calculation run again from the raw data
    • A written list of where we agree and where we do not
    • A call with the lender’s credit committee
    Request a review
Scoping call
FreeThirty minutes with an engineer.
Operational Reassessment
From £11,500For a single farm. A portfolio is quoted as one fee.
Measurement Campaigns
£6,200 a monthA lidar unit, installed, monitored and insured, for a minimum of 12 months. Masts are quoted for each site.
Repowering and Hybrid Studies
From £16,000New turbines in place of old ones, or solar or storage added.
Offshore wind
QuotedAn Energy Yield Assessment for offshore wind is quoted for each project.
Reliance letter
£1,200For each further lender. A letter for one lender is included in every assessment.

1,460 projects assessed since 2012

Founded in 2012 in Edinburgh by an atmospheric physicist and a wind engineer, after both had spent years at a turbine maker checking other firms’ estimates against what the farms later produced.

The firm in figures

Projects assessed since 2012, to October 2026

1,460

Wind and solar capacity assessed, in 31 countries

38 GW

Project debt raised on reports we wrote or reviewed

£9.4 billion

Lenders have accepted our reports

64

Reports in 2025 issued on or before the agreed date

97%

46 staff

November 2026

Analysts and engineers
29
Measurement technicians
6
Software and data
5
In the office
6

The 2026 validation study

Published every year. The 2026 study, issued in September 2026, covers 212 operating farms that we assessed before they were built, each with at least three years of production data: 148 wind farms and 64 solar farms, in 19 countries. It names every farm that fell short by more than 10%, and says why.

What clients say

2026 validation study

212 operating farms in 19 countries

Produced, on average

99.6%

of our P50 estimate

Farms within 6% of their estimate88%

Wind farms
148
Solar farms
64

Standards

  • ISO 9001:2015

    Certified since 2015

    Quality system

    Certified to ISO 9001:2015, and has been since 2015.

  • ISO/IEC 17025

    Accredited since 2018

    Measurement work

    Accredited to ISO/IEC 17025, and has been since 2018.

  • ISO/IEC 27001

    Certified since 2021

    Information security

    Client data is held in the United Kingdom and the European Union.

What clients say

  • “Skerrow’s P90 was lower than the figure we had been carrying. They were right, and the bank knew they would be.”

    Marta Lindqvist

    Head of development

    Solveig Kraft

  • “We send them the assessments we are asked to lend against. They re-run the numbers from the raw data, and the report says plainly where they disagree.”

    Owen Barraclough

    Director of project finance

    Castellan Project Finance

  • “Three years on, the farm is within one percent of their estimate. That is the only review of a consultant that matters.”

    Farah Siddiqui

    Asset manager

    Northmoor Renewables

The people

46 staff in November 2026: 29 analysts and engineers, 6 measurement technicians, 5 in software and data, and 6 in the office.

  • Dr Isla Renwick

    Managing director and co-founder

    Atmospheric physicist. Wrote the firm’s long-term correction method, which is published in full.

  • Tomas Achterberg

    Technical director and co-founder

    Wind engineer. Has checked more than 600 of the firm’s reports.

  • Dr Priyanka Nair

    Head of offshore wind

    Joined in 2016 from a research institute for offshore meteorology.

  • Amara Okonkwo-Hale

    Head of solar

    Built the solar practice from 2017, now a third of the firm’s work.

  • Callum Ferreira

    Head of measurement

    Runs the campaigns: 41 masts and 23 lidar units in the field in November 2026.

  • Henrike Vossler

    Head of the Hamburg office

    Opened the office in 2020.

Request an assessment

A request is answered within one working day, by an engineer. We are booking assessments that start in January 2027.

Phone
+44 131 496 0127Monday to Friday, 8:30am to 5:30pm UK time
Edinburgh
Head office
4 Tarbrax RowEdinburgh EH6 5NPUnited Kingdom
Hamburg
Opened in 2020, for clients in Germany, the Nordic countries and Poland
Speicherhof 1220457 HamburgGermany

The scoping call is thirty minutes with an engineer, and free.

This is a Designhouse template.Use this template